Center-pivot irrigation calculator

Calculate irrigated area, gross/net depth, pass time and required flow for a center pivot.

Method: Circular sector · water accounting

Open this calculator →

Inputs and units

Use measurements representative of your field, crop or irrigation system. The values below are illustrative examples.

InputUnitExample value
Irrigated radius (end gun excluded)m400.000
Irrigated sector angledegrees360.000
Measured total system flowL/s50.000
Time for one pass over this sectorh24.000
Application efficiency%85.000
Target net irrigation depthmm10.000

Worked example

These are calculated demonstration values from the existing tool, not measured field results or a site-specific recommendation.

Calculated quantityExample resultUnit
Irrigated sector area50.265ha
Delivered water per pass4,320.000m³
Gross mean depth per pass8.594mm
Estimated net depth per pass7.305mm
Time for the target net depth32.853h
Flow for target at entered pass time68.444L/s
Whole-area equivalent application rate0.358mm/h
Angular travel rate15.000degrees/h
Net depth minus target-2.695mm

Water accounting for one pass over the selected circular sector. Confirm measured flow, application efficiency and the actual irrigated boundary in the field.

Whole-area equivalent mm/h is flow divided by the complete sector area. It is not the instantaneous application rate under the outer sprinklers and must not be used alone for an infiltration or runoff check.

The duration refers to one pass over the entered angle. End guns, corner arms, overlaps, obstacles, variable-rate sectors and downtime are excluded. No timer setting or pump/valve control is calculated.

Check the nozzle package, pressure losses, wetted width, soil intake, slope and manufacturer limits separately. A center-pivot uniformity test needs radial area weighting; the drip-emitter CU tool does not provide that test.

Assumptions and limitations

  • The radius is the actual irrigated circular radius; end guns and corner systems are excluded. The selected sector is watered once with constant total flow.
  • Efficiency is an explicit user estimate of useful root-zone storage, not a quantity inferred from pivot type, uniformity or weather. Net target should account for rainfall and soil water separately.
  • This preliminary accounting does not design the lateral, nozzle package, pressure regulation, pump, local peak application rate or mechanical travel settings.

Use your measurements in this calculator →

Public method guides and labelled examples are freely readable. Phase 1 calculations, weather data and exports are free without registration. Register with a verified email only to save private work or upload a personal station dataset.

Related guides

All Field Tools →

Sources

Conservation of water for a circular/sector pass, expressed in SI. Field-average depth and local sprinkler intensity are different quantities.